  • Product description: Sieno switchgears 160W12V Switching Power Supply Unit Battery Back up Charger with UPS Function Features: ·AC input voltage range selected by switch ·Small volume,low weigh
  • INQUIRY

Sieno switchgears 160W 12V Switching Power Supply Unit Battery Back up Charger with UPS Function

Features:

      ·AC input voltage range selected by switch

 

        ·Small volume,low weight,high efficiency

 

        ·Protections:short circuit/over load

 

        ·Indicator for power on/charge/normal(LED)

 

        ·100% full load burn-in test

 

        ·Battery protection at low voltage

 

        ·2 Year warranty

 

Model

SC-160-12

SC-160-24

 

 

 

output

DC voltage

CH1:13.8V

CH1:13.4V

CH1:27.6V

CH2:26.5V

Voltage tolerance

±1%

-----

±1%

-----

Rated current

11A

0.6A

5A

0.5A

Current range

0~11A

-----

0~5A

-----

Rated power

151.8W

13.8W

Ripple&noise

120mvp-p

-----

180mvp-p

-----

DCvoltage ADJ.range

CH1:11.3~14.9V

CH1:21.3~29.8V

 

 

input

Voltage range

90~264VAC,127~370VDC

frequency

47~63HZ

AC current

2.8A/115VAC,1.4A/230VAC

efficiency

83%

85%

Inrush current

Cold start current  30A/115VAC,50A/230VAC

Leakage current

< 1mA/240VAC

 

protection

Over load

Rated output power110%~150%  start over load protection

protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed

Battery protection

At low voltage

9.5~11V

20~22V

protection mode:cutoff output

Function

UPS introduction

long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop harging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard,

cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs

environment

Working temp,humidity

-10ºC~+60ºC,20%~90%RH

Storagetemp,humidity

-20ºC~+85ºC,10%~95%RH non-condensing

Withstand vibration

10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes

safety

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC

Fitstandard

Safety standard

Compliance to UL60950-1

EMC standard

Compliance to EN55022,CLASSB

others

Dimension

159*97*38mm (L*W*H)

Weight/packing

0.56kg/45pcs/26kg/0.041m³/1.45CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.