Thermal overload relay

  • Sieno GTH-40 thermal overload relay
  • Sieno GTH-40 thermal overload relay
  • Sieno GTH-40 thermal overload relay
  • Sieno GTH-40 thermal overload relay
Sieno GTH-40 thermal overload relaySieno GTH-40 thermal overload relaySieno GTH-40 thermal overload relaySieno GTH-40 thermal overload relay

Sieno GTH-40 thermal overload relay

  • GTH series thermal relay is used in the circuit of 50/60Hz, rated insulation voltage 660V,rated current 0.1-85A for protecting the phase break when the electric motor is overloaded. Therelay has diffe
  • Product description: Sieno GTH-40 thermal overload relay
  • INQUIRY

Sieno GTH-40 thermal overload relay

GTH series thermal relay is used in the circuit of 50/60Hz, rated insulation voltage 660V,rated current 0.1-85A for protecting the phase break when the electric motor is overloaded. Therelay has different mechanism and temperature compensation. It can be plugged in CJX5 seriesAC contactor. The product conforms to IEC60947-4-1.


Technical Data:

Motion Characteristic: Three-phase Balance Motion Tim

No Times of the setting current(A) Motion time Start conidition Ambient temperature
1 1.05 >2h Cold state 20±5oC
2 1.2 <2h Heat state (Following the No.1 test)
3 1.5 <4min
4 7.2 10A 2s< Tp ≤10s ≤63A Cold state
10 4s< Tp ≤10s >63A


No Times the setting current(A) Motion time Start condition Ambient temperature
Any two phases Another phase
1 1.0 0.9 >2h Cold state 20±5oC
2 1.15 0 <2h Heat state(Following the No.1 test)


Phase-losing Motion Characteristic


Ratings Type GTH-22 GTH-40 GTH-85
Nominal current Ranges Ranges Ranges
Min. Mid. Max. Min. Mid. Max. Min. Mid. Max.
Rated current(A) 0.14 0.1 0.14 0.16
0.21 0.16 0.21 0.25
0.33 0.25 0.33 0.4
0.52 0.4 0.52 0.63
0.82 0.63 0.82 1
1.3 1 1.3 1.6
2.1 1.6 2.1 2.5
3.3 2.5 3.3 4
5 4 5 6 4 5 6
6.5 5 6.5 8 5 6.5 8
7.5 6 7.5 9 6 7.5 9
8.5 7 8.5 10 7 8.5 10 7 8.5 10
11 9 11 13 9 11 13 9 11 13
15 12 15 18 12 15 18 12 15 18
19 16 19 22 16 19 22 16 19 22
22 18 22 26 18 22 26
30 24 30 36 24 30 36
34 28 34 40 28 34 40
42 34 42 50
55 45 55 65
65 54 65 75
74 63 74 85
Element No. 2 heaters Standard Standard Standard
3 heaters Option Option Option
Aux. Contact 1NO 1NC 1NO 1NC 1NO 1NC
Reset type Auto/Manual Auto/ Manual Auto/Manual
Power consumption 1.8VA/heater 1.8VA/heater 1.8VA/heater
Separate mounting unit AZ-22H AZ-40H AZ-85H
Other model GTH-22/3 GTH-40/3 GTH-85/3
GTH-22 GTH-40 GTH-85
GTH-22/L GTH-40/L GTH-85/L
Applied contactors GMC-9,12,18,22 GMC-32,40 GMC-50,65,75



CONTACT US

Address

Liushi,Yueqing,Wenzhou,Zhejiang,China

Phones

86-18657769510