Model
|
LPV-80-12
|
LPV-80-24
|
LPV-80-36
|
LPV-80-48
|
output
|
DC voltage
|
12V
|
24V
|
36V
|
48V
|
Voltage tolerance
|
±1%
|
±1%
|
±1%
|
±1%
|
Rated current
|
6.6A
|
3.3A
|
2.2A
|
1.7A
|
Current range
|
0~6.6A
|
0~3.3A
|
0~2.2A
|
0~1.7A
|
Rated power
|
79.2W
|
79.2W
|
79.2W
|
81.6W
|
Ripple&noise
|
100mvp-p
|
150mvp-p
|
150mvp-p
|
180mvp-p
|
input
|
Voltage range
|
90~264VAC,126~373VDC
|
Frequency
|
47~63HZ
|
AC current
|
2A/115VAC, 1A/230VAC
|
Efficiency
|
82%
|
84%
|
84%
|
85%
|
Inrush current
|
Cold start current 18A/115VAC, 36A/230VAC
|
Leakage current
|
<1mA/240VAC
|
protection
|
Over load
|
Rated output power 115%~135%start over load protection
|
Protection type:hiccup mode,auto-recovery after fault condition is removed
|
Over voltage
|
15.6~17.8V
|
30.6~33.2V
|
42.6~44.2V
|
54.8~56.6V
|
Protection type:hiccup mode,auto-recovery after fault condition is removed
|
Over temperature
|
Shell temp≥85℃,start over temperature protection
|
Protection mode:cutoff output,auto-recovery after temperature become normal
|
environment
|
Working temp,humidity
|
-10℃~+60℃,20%~90%RH
|
Storage temp.humidity
|
-20℃~+85℃,10%~95%RH non condensing
|
Withstand vibration
|
10~500HZ,2G 10min/1cycle,period for 60minutes,each axes
|
safety
|
Withstand voltage
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolated resistance
|
I/P-O/P、I/P-FG、O/P-FG:100M ohms/500VDC
|
Fits
|
Safety standard
|
Fit UL1012,IP67 protect level
|
|
tandard
|
EMC standard
|
Fit EN55022,CLASSA
|
Others
|
Dimension
|
185*69*43mm (L*W*H)
|
Weight/packing
|
0.9kg/20pcs/19kg/0.026 m³/0.91CUFT
|
Note
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
|
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
|
3. Tolerance : includes set up tolerance, line regulation and load regulation.
|