DW45/W1 series intelligent breaker is applicable in the distribution network of AC 50Hz, rated voltage
of 400V and 690V and rated current from 630A~6300A, to distribute electric energy protection
circuit and prevent power equipments from harm of overload, under-voltage,short circuit and
single-phase earthing etc.
Provided with intelligent protecting function and precise selective protection, breaker can enhance
the dependability of power supply and avoid the unexpected power cut.
This product accords with the standard of IEC60947-2.
Keyword:3P,4Pole, 630A-6300A, 80kA-120kA, Fixed type and drawable type, Electric and manual
Main Datasheet
CE Indoor DC DW45 4 Pole 5000A Air Circuit Breaker Condition
Installation mode:fixed type, drawable type.
Operation mode:motor operated, manually operated(for serving).
Pole number:three pole, four pole.
Release type:intelligent type over-current controller,under-voltage instantaneous(or time-delay) operation release:shunt release.
The properties of intelligent type over-current controller:
a.Long time delay over-current protection inverse time limit, short time delay over-current protection inverse time limited, short time delay over current protection fixed time limit, instantaneous.
b.Single-phase earthing protection function.
c.Presenting function:setting current lr,action current, setting time, action time.
d.Alarming function:overload alarming
e.Self-checking function:over-heat protection,microcomputer self diagnosing.
f.Testing function
g.Load monitoring function.
h.Thermal simulation function.
i.MCR function.
j.Fault memory function.
Ambient Temperature:
a.Temperature:40℃≥T≥5℃ average value for 24 hours≤35℃
Note:working condition of minimum temperature is -10℃ or -25℃, users must declare while ordering;
Working condition of maximum temperature exceed 40℃ or minimum temperature under -25℃,the users should consult with our factory.
b.Altitude:2000m.
c.Air relative humidity:50%, when the max temperature is 40℃ and can be more while the temperature is lower, monthly average temperature in the most humid month 25℃,monthly average maximum relative humidity 90%.
d.Pollution grade:3.
e.Installation type: the type of circuit breaker, main circuit, under-voltage tripping coil and supply transformer is IV,the type of other ancillary circuit,controlling circuit is.
F. Installation condition:installation of circuit breaker shall accord to the instruction,and the vertical gradient of installation place should not exceed 5°.
Outline Size
ACCESSORIES
operation, Intelligent controller, shunt release, Suitable for photovoltaic systems
Frame size rated
Current inm(A)
Rated Current
InA
Rated Insulation
Votlage (V)
Rated limit short-circuit breaking
Capacity Icu(kA)
Rated operating short-circuit
breaking
Capacity Icu(kA)
Rated short-time
withstand
Current IcwkA(1s)
400V
690V
400V
690V
2000
630
690
80
50
50
40
50
800
1000
1250
1600
2000
3200
2000
100
65
65
50
65
2500
3200
4000
3200
100
65
65
50
65/80
3600
4000
6300
4000
120
80
80
70
85/100
5000
6300
Contact: Ms.Kelly Cao