  • CE Indoor DC DW45 4 Pole 5000A Air Circuit Breaker Condition Installation mode:fixed type, drawable type. Operation mode:motor operated, manually operated(for serving). Pole number:three pole, four
  • Product description: Sieno DW45 draw-type-air-circuit-breaker ACB
  • INQUIRY



Sieno DW45 draw-type-air-circuit-breaker ACB

DW45/W1 series intelligent breaker is applicable in the distribution network of AC 50Hz, rated voltage

of 400V and 690V and rated current from 630A~6300A, to distribute electric energy protection

circuit and prevent power equipments from harm of overload, under-voltage,short circuit and

single-phase earthing etc.

Provided with intelligent protecting function and precise selective protection, breaker can enhance

the dependability of power supply and avoid the unexpected power cut.

This product accords with the standard of IEC60947-2.

 

Keyword:3P,4Pole, 630A-6300A, 80kA-120kA, Fixed type and drawable type, Electric and manual
operation, Intelligent controller, shunt release, Suitable for photovoltaic systems

 

Main Datasheet

Frame size rated
Current inm(A) 
Rated Current
InA
Rated Insulation 
Votlage (V)
Rated limit short-circuit breaking
Capacity Icu(kA) 
Rated operating short-circuit 
breaking 
Capacity Icu(kA)
Rated short-time 
withstand 
Current IcwkA(1s)
      400V 690V 400V 690V  
2000 630 690 80 50 50 40 50
800
1000
1250
1600
2000
3200 2000 100 65 65 50 65
2500
3200
4000 3200 100 65 65 50 65/80
3600
4000
6300 4000 120 80 80 70 85/100
5000
6300

 

CE Indoor DC DW45 4 Pole 5000A Air Circuit Breaker Condition

Installation mode:fixed type, drawable type.

Operation mode:motor operated, manually operated(for serving).

Pole number:three pole, four pole.

Release type:intelligent type over-current controller,under-voltage instantaneous(or time-delay) operation release:shunt release.

The properties of intelligent type over-current controller:

a.Long time delay over-current protection inverse time limit, short time delay over-current protection inverse time limited, short time delay over current protection fixed time limit, instantaneous.

b.Single-phase earthing protection function.

c.Presenting function:setting current lr,action current, setting time, action time.

d.Alarming function:overload alarming

e.Self-checking function:over-heat protection,microcomputer self diagnosing.

f.Testing function

g.Load monitoring function.

h.Thermal simulation function.

i.MCR function.

j.Fault memory function.

Ambient Temperature:

a.Temperature:40T5 average value for 24 hours35

Note:working condition of minimum temperature is -10 or -25, users must declare while ordering;

Working condition of maximum temperature exceed 40 or minimum temperature under -25,the users should consult with our factory.

b.Altitude:2000m.

c.Air relative humidity:50%, when the max temperature is 40 and can be more while the temperature is lower, monthly average temperature in the most humid month 25,monthly average maximum relative humidity 90%.

d.Pollution grade:3.

e.Installation type: the type of circuit breaker, main circuit, under-voltage tripping coil and supply transformer is IV,the type of other ancillary circuit,controlling circuit is.

F. Installation condition:installation of circuit breaker shall accord to the instruction,and the vertical gradient of  installation place should not exceed 5°.

 