AC contactor-CJX2 Series

  • Sieno CJX2-F185 Electromotor Circuit Contactor
  • Sieno CJX2-F185 Electromotor Circuit Contactor
  • Sieno CJX2-F185 Electromotor Circuit Contactor
  • Sieno CJX2-F185 Electromotor Circuit Contactor
Sieno CJX2-F185 Electromotor Circuit ContactorSieno CJX2-F185 Electromotor Circuit ContactorSieno CJX2-F185 Electromotor Circuit ContactorSieno CJX2-F185 Electromotor Circuit Contactor

Sieno CJX2-F185 Electromotor Circuit Contactor

  • ​CJX2-F185 AC contactor (hereinafter to be referred as contactor), it mainly applies to the circuit of AC 50Hz/60Hz, and rated insulating voltage 1000V.
  • When used in AC-3 and rated operational voltage 380V, the rated current up to 800A, for long distance breaking circuit and frequently starting or control the motor.
  • Combined with electromagnetic starter and proper thermal overload relay can protect load circuit. Contactor can frequently start adn control AC electromotor.
  • Product description: Sieno CJX2-F185 Motor AC Contactor
  • INQUIRY

Sieno CJX2-F185 Electromotor Circuit Contactor

CJX2-F185 AC contactor (hereinafter to be referred as contactor), it mainly applies to the circuit of AC 50Hz/60Hz, and rated insulating voltage 1000V. When used in AC-3 and rated operational voltage 380V, the rated current up to 800A, for long distance breaking circuit and frequently starting or control the motor. Combined with electromagnetic starter and proper thermal overload relay can protect load circuit. Contactor can frequently start adn control AC electromotor.

Normal running and installation conditions

  1. Ambient air temperature: -5!+40, the average value should not exceed +35 within 24 hours.

  2. Elevation: at most 2000m.

  3. Atmospheric conditions: When the temperature at 40, the relative humidity of atomsphere should be at the most 50%. When at relatively low temperatures, it could have higher relative humidity. Monthly maximum relative humidity could be not more than 90%. Special measures should be taken due to occurrence of dews.

  4. Class of pollution: Class 3

  5. Installation conditions: Degree of inclination between fitting surface and vertical surface should not exceed


Model meaning

CJX2-F model meaning.jpg

Detail

CJX2-F Detail.jpg


Technical Data:


Type
Rated operational current AC-3(A) Max power ratings of 3-phase motors in category AC-3(KW)
Operating frequency (time/hour) AC-3 Electrical life AC-3*10 Mechanical life*10
220V
230V
380V
400V
415V 440V 500V 660V
690V
1000V
CJX2-F185 185 55 90 100 100 110 110 100 6000000 1000000 6000000